Dr. Madita Göb

Photo of Madita  Göb

Wissenschaftliche Mitarbeiterin/Postdoc

AG Huber
Universität zu Lübeck
Institut für Biomedizinische Optik

Peter-Monnik-Weg 4
23562 Lübeck
Gebäude 81, Raum 61

Email: m.goeb(at)uni-luebeck.de
Phone: +49 451 3101 3262
Fax: +49 451 3101 3233



2021

Madita Göb, Sazgar Burhan, Wolfgang Draxinger, Jan Philip Kolb, and Robert Huber,
Towards densely sampled ultra-large area multi-MHz-OCT for in vivo skin measurements beyond 1 cm2/sec, in European Conferences on Biomedical Optics 2021 (ECBO) , Optical Society of America, Dec.2021. pp. EW3C.4.
DOI:10.1117/12.2616054
Bibtex: BibTeX
@inproceedings{Gob:21,
author = {Madita G\"{o}b and Sazgar Burhan and Wolfgang Draxinger and Jan Philip Kolb and Robert Huber},
booktitle = {European Conferences on Biomedical Optics 2021 (ECBO)},
journal = {European Conferences on Biomedical Optics 2021 (ECBO)},
keywords = {AG-Huber_OCT;Fourier domain mode locking; Image processing; Image quality; Optical coherence tomography; Temporal resolution; Three dimensional imaging},
pages = {EW3C.4},
publisher = {Optical Society of America},
title = {Towards densely sampled ultra-large area multi-MHz-OCT for in vivo skin measurements beyond 1 cm$^2$/sec},
year = {2021},
url = {http://www.osapublishing.org/abstract.cfm?URI=ECBO-2021-EW3C.4},
abstract = {We demonstrate a 3.3 MHz A-scan rate OCT for rapid scanning of large areas of human skin. The mosaicking performance and different OCT imaging modalities including intervolume speckle contrast are evaluated.},
}
Simon Lotz, Christin Grill, Madita Göb, Wolfgang Draxinger, Jan Philip Kolb, and Robert Huber,
Cavity length control for Fourier domain mode locked (FDML) lasers with µm precision, Biomedical Optics Express , vol. 12(5), pp. 2604-2616, Mar. 2021.
DOI:10.1364/BOE.422898
Bibtex: BibTeX
@article{Lotz2021,
   author = {S. Lotz, C. Grill, M. Göb, W. Draxinger, J.P. Kolb and R. Huber},
   title = {Cavity length control for Fourier domain mode locked (FDML) lasers with µm precision},
   journal = {Biomedical Optics Express},
   volume = {12(5)},
   keywords={AG-Huber_FDML},
   pages = {2604-2616},
   url = {https://doi.org/10.1364/BOE.422898},
   year = {2021},
   type = {Journal Article}
}
Simon Lotz, Christin Grill, Madita Göb, Wolfgang Draxinger, Jan Philip Kolb, and Robert Huber,
Characterization of the dynamics of an FDML laser during closed-loop cavity length control, in Fiber Lasers XVIII: Technology and Systems , Michalis N. Zervas, Eds. SPIE, 2021. pp. 236 -- 241.
DOI:10.1117/12.2578514
Bibtex: BibTeX
@inproceedings{LotzLASE2021,
author = {S. Lotz, C. Grill, M. Göb, W. Draxinger, J. P. Kolb and R. Huber},
title = {{Characterization of the dynamics of an FDML laser during closed-loop cavity length control}},
volume = {11665},
booktitle = {Fiber Lasers XVIII: Technology and Systems},
editor = {Michalis N. Zervas},
organization = {International Society for Optics and Photonics},
publisher = {SPIE},
pages = {236 -- 241},
abstract = {In Fourier domain mode locked (FDML) lasers, extremely precise and stable matching of the filter tuning period and light circulation time in the cavity is essential for ultra-low noise operation. During the operation of FDML lasers, the ultra-low noise mode can be lost due to temperature drifts of the already temperature stabilized cavity resulting in increased intensity noise. Until now, the filter frequency is continuously regulated to match the changing light circulation time. However, this causes the filter frequency to constantly change by a few mHz and leads to synchronization issues in cases where a fixed filter frequency is desired. We present an actively cavity length controlled FDML laser and a robust and high precision feedback loop algorithm for maintaining ultra-low noise operation. Instead of adapting the filter frequency, the cavity length is adjusted by a motorized free space beam path to match the fixed filter frequency. The closed-loop system achieves a stability of ~0.18 mHz at a sweep repetition rate of ~418 kHz which corresponds to a ratio of 4×10<sup>-10</sup>. We investigate the coherence properties during the active cavity length adjustments and observe no noise increase compared to fixed cavity length. The cavity length control is fully functional and for the first time, offers the possibility to operate an FDML laser in sweet spot mode at a fixed frequency or phase locked to an external clock. This opens new possibilities for system integration of FDML lasers.},
keywords = {AG-Huber_FDML, FDML, Fourier domain mode locking, laser beating, tunable laser, optical coherence tomography, OCT},
year = {2021},
URL = {hhttps://doi.org/10.1117/12.2578514}
}

2020

Tom Pfeiffer, Madita Göb, Wolfgang Draxinger, Sebastian Karpf, Jan Philip Kolb, and Robert Huber,
Flexible A-scan rate MHz-OCT: efficient computational downscaling by coherent averaging, Biomed. Opt. Express , vol. 11, no. 11, pp. 6799--6811, Nov. 2020. OSA.
DOI:10.1364/BOE.402477
Bibtex: BibTeX
@article{Pfeiffer:20,
author = {T. Pfeiffer, M. G\"{o}b, W. Draxinger, S. Karpf, J.P. Kolb and R. Huber},
journal = {Biomed. Opt. Express},
keywords = {AG-Huber_OCT; High speed imaging; Image quality; Optical coherence tomography; Swept lasers; Swept sources; Systems design},
number = {11},
pages = {6799--6811},
publisher = {OSA},
title = {Flexible A-scan rate MHz-OCT: efficient computational downscaling by coherent averaging},
volume = {11},
month = {Nov},
year = {2020},
doi = {10.1364/BOE.402477},
abstract = {In order to realize adjustable A-scan rates of fast optical coherence tomography (OCT) systems, we investigate averaging of OCT image data acquired with a MHz-OCT system based on a Fourier Domain Mode Locked (FDML) laser. Increased system sensitivity and image quality can be achieved with the same system at the cost of lower imaging speed. Effectively, the A-scan rate can be reduced in software by a freely selectable factor. We demonstrate a detailed technical layout of the strategies necessary to achieve efficient coherent averaging. Since there are many new challenges specific to coherent averaging in swept source MHz-OCT, we analyze them point by point and describe the appropriate solutions. We prove that coherent averaging is possible at MHz OCT-speed without special interferometer designs or digital phase stabilization. We find, that in our system up to \&\#x223C;100x coherent averaging is possible while achieving a sensitivity increase close to the ideal values. This corresponds to a speed reduction from 3.3 MHz to 33 kHz and a sensitivity gain of 20 dB. We show an imaging comparison between coherent and magnitude averaging of a human finger knuckle joint in vivo with 121\&\#x00A0;dB sensitivity for the coherent case. Further, the benefits of computational downscaling in low sensitivity MHz-OCT systems are analyzed.},
}

2019

Madita Göb, Tom Pfeiffer, and Robert Huber,
Towards combined optical coherence tomography and multi-spectral imaging with MHz a-scan rates for endoscopy, in Optical Coherence Imaging Techniques and Imaging in Scattering Media III , aciej Wojtkowski and Stephen A. Boppart and Wang-Yuhl Oh, Eds. Jul.2019. pp. 110780Y.
DOI:10.1117/12.2526796
Bibtex: BibTeX
@inproceedings{10.1117/12.2526796,
author = {Madita G{\"o}b and Tom Pfeiffer and Robert Huber},
title = {{Towards combined optical coherence tomography and multi-spectral imaging with MHz a-scan rates for endoscopy}},
volume = {11078},
booktitle = {Optical Coherence Imaging Techniques and Imaging in Scattering Media III},
editor = {Maciej Wojtkowski and Stephen A. Boppart and Wang-Yuhl Oh},
organization = {International Society for Optics and Photonics},
publisher = {SPIE},
pages = {110780Y},
abstract = {We demonstrate a preliminary setup of a combined MHz-OCT and RGB narrowband reflection microscope and investigate the performance of the new RGB branch and different display modes of colored OCT data sets.},
keywords = {MHz OCT, multi-spectral imaging, Optical Coherence Tomography, Fourier Domain Mode Locked , FDML, RGB, Color },
year = {2019},
doi = {10.1117/12.2526796},
URL = {https://doi.org/10.1117/12.2526796}
}